호라이즌 스택과 완벽히 호환되는 6000W DC 전자로드시리즈 (M-9718 시리즈)

Feature:
- Six high speed operation modes: CC,CR,CV,CW,CC+CV,CR+CV
- Over current, over voltage, over power, over heating and polarity reversal protection
- High-luminance vacuum fluorescent display (VFD) screen with two line, four channel display
- Intelligent fan system will automatically activate based on changing ambient temperatures
- Soft-start time setting, activating the power supply in accordance with the set voltage value
- Battery test and short-circuit test functions
- Capable of rising edge and falling edge dynamic testing
- Supporting external triggeron either in
- put or output
- External current waveform monitor terminal output terminal
- Supports remote voltage compensation and multi-data storage
- Power-on-self-test, software calibration and standard rack mountable
- Edits arbitrary waveforms in list function
- Available with RS232 / RS485 / USB serial interfaces.
Application:
M97XX series have wide application from production lines for cell phone chargers, cell phone batteries, electronic vehicle batteries, switching power supplies, linear power supplies, and LED drivers, to research institute, automotive electronic, aeronautic and astronautic, maritime, solar celland fuel cell etc.test and measurement applications.
Specification: (M-9718)
고객의 요청에 따라, 10kW - 30kW - 50kW - 100kW - 200kW 까지 커스텀 제작이 가능합니다.
|
Model |
M-9718 | ||
|
Input
Rating |
Power |
6000W | |
|
Current |
0-240A | ||
|
Voltage |
0-150V | ||
|
CC Mode |
Range |
0-24A |
0-240A |
|
Resolution |
1mA |
10mA | |
|
Accuracy |
0.05%+0.05%FS |
0.1%+0.05%FS | |
|
CV Mode |
Range |
0.1-19.999V |
0.1-150V |
|
Resolution |
1mV |
10mV | |
|
Accuracy |
0.03%+0.02%FS |
0.03%+0.02%FS | |
|
CR
Mode (Voltage and current input value >=10% full
measurement) |
Range |
0.3-10K Oh |
0.3-5K Oh |
|
Resolution |
16 bit |
16 bit | |
|
Accuracy |
0.1%+0.1%FS |
0.1%+0.1%FS | |
|
CW
Mode (Voltage and current input value >=10% full
measurement) |
Range |
0-6000W |
0-6000W |
|
Resolution |
1mW |
10mW | |
|
Accuracy |
0.1%+0.1%FS |
0.1%+0.1%FS | |
|
Voltage
Measurement |
Voltage |
0-19.999V |
0-150V |
|
Resolution |
1mV |
10mV | |
|
Accuracy |
0.015%+0.03%FS |
0.015%+0.03%FS | |
|
Current
Measurement |
Current |
0-24A |
0-240A |
|
Resolution |
0.1mA |
1mA | |
|
Accuracy |
0.03%+0.05%FS |
0.1%+0.08%FS | |
|
Power
Measurement(Voltage and current input value >=10% full
measurement) |
Power |
100W |
6000W |
|
Resolution |
1mW |
10mW | |
|
Accuracy |
0.1%+0.1%FS |
0.1%+0.1%FS | |
|
Battery
Test |
Battery
Input:0.5-120V;Max. Measurement:Capacity=999AH;Resolution=0.1mA; Time
Range=1S-16H | ||
|
Dynamic
Test |
Dynamic List: 0-25kHZ;
2.5A/uS; T1&T2:60uS-999S; Accuracy:+15% offset+10%FS | ||
|
Current
soft-startup Time |
1mS;2mS;5mS;10mS;20mS;50mS;100mS;200mS
Accuracy:+15% offset+10%FS | ||
|
Short
Circuit |
Current(CC) |
=26.4A |
=264A |
|
Voltage(CV) |
0V | ||
|
Resistance(CR) |
=7mOh | ||
|
Temperature |
Operating |
0~40oC | |
|
Nonoperating |
-10oC~70oC | ||
|
Dimension |
W*H*D(mm) |
489.5*357*538.5 | |
|
Weight |
Kg |
70 | |